3-35 (E)
BVP-9500WS/9500WSP MM
B
A
B
A
[NTSC]
[PAL]
3-3-16. MONITOR Gain Adjustment
Equipment:
Waveform monitor
Test point:
TEST OUT connector/side panel
Preparations
.
Extend the EN-141 board with the extension board (EX-762 board assemby or EX-464.)
.
Connect the waveform monitor to the TEST OUT connector/side panel.
.
Disconnect the triax cable or optical fiber cable from CCU.
.
Supply power from the AC adaptor (AC-550/550CE).
.
OUTPUT switch/ side panel
→
BARS
Adjustment procedures
1.
Select G signal by pushing down the TEST OUT switch (side panel) from the RGB position towards
the SEL position. (You can check which signal is selected on the viewfinder screen.)
2.
Adj. point:
1
RV801 (RGB SYNC) /EN-141 board
Specification:
A = 40
±
1 IRE [NTSC]
A = 300
±
5 mV [PAL]
3.
Adj. point:
1
RV800 (RGB LEV) /EN-141 board
Specification:
B = 100
±
1 IRE [NTSC]
B = 700
±
5 mV [PAL]
Setting after adjustment
.
Connect the CCU with a triax cable or optical fiber cable.
.
Power off and return EN-141 board to its normal position.
3-3. Encoder System Adjustment
Summary of Contents for BVP-9500WS
Page 62: ......
Page 72: ......
Page 206: ......
Page 234: ......
Page 236: ......
Page 246: ......
Page 252: ......
Page 270: ......
Page 277: ......
Page 282: ......
Page 296: ......
Page 322: ......
Page 324: ......
Page 338: ......
Page 340: ......
Page 342: ......
Page 346: ......
Page 350: ......
Page 356: ......
Page 358: ......
Page 360: ......
Page 362: ......
Page 368: ......
Page 372: ......
Page 378: ......
Page 380: ......
Page 382: ......
Page 389: ......