3-21 (E)
BVP-9500WS/9500WSP MM
B
A
B
A
[NTSC]
[PAL]
3-3-3. G Level Adjustment
Equipment:
Oscilloscope
Preparations
.
Extend the EN-141 board with the extension board (EX-762 board assembly or EX-464.)
.
Disconnect the triax cable or optical fiber cable from CCU.
.
Supply power from the AC adaptor (AC-550/550CE).
.
OUTPUT switch/side panel
→
BARS
Adjustment procedures
1.
Test point:
TP2/EN-141 board
GND:
E1/EN-141 board
Adj. point:
1
RV204 (G BL) /EN-141 board
Specification:
A = 0
±
5 mV
2.
Test point:
TP2/EN-141 board
GND:
E1/EN-141 board
Adj. point:
1
RV200 (G LEV) /EN-141 board
Specification:
B = 1200
±
10 mV
3-3. Encoder System Adjustment
Summary of Contents for BVP-9500WS
Page 62: ......
Page 72: ......
Page 206: ......
Page 234: ......
Page 236: ......
Page 246: ......
Page 252: ......
Page 270: ......
Page 277: ......
Page 282: ......
Page 296: ......
Page 322: ......
Page 324: ......
Page 338: ......
Page 340: ......
Page 342: ......
Page 346: ......
Page 350: ......
Page 356: ......
Page 358: ......
Page 360: ......
Page 362: ......
Page 368: ......
Page 372: ......
Page 378: ......
Page 380: ......
Page 382: ......
Page 389: ......