User Manual
EM100 Mini Inverter
80
Figure 6-15 V/F Curves
Description:
F05.00=0 Automatic torque boost
F05.00=1
~
10 Fixed torque boost curve
F05.00=11
~
20 Oil pump motor boost curve
F05.00=21
~
30 Synchronous motor boost curve
F05.00=31
~
34 Blower/water pump boost curve
F05.00=35 Customer defined V/F curve scaling
F05.00
≠
35
Select a fixed V/F boost curve, the output of Ue is corresponding to the setting
value of F05.01.
No.
Function
Range
Unit Default
Type
F05.02
Voltage 1
0.00
~
100.00
% 1.00
●
F05.03
Voltage 2
0.00
~
100.00
%
4.00
●
F05.04
Voltage 3
0.00
~
100.00
%
10.00
●
F05.05
Voltage 4
0.00
~
100.00
%
16.00
●
F05.06
Frequency 1
0.00
~
Frequency 2
% 1.00
●
F05.07
Frequency 2
Frequency 1~ Frequency 3
%
4.00
●
F05.08
Frequency 3
Frequency 2~ Frequency 4
%
10.00
●
F05.09
Frequency 4
Frequency 3
~
100.00
%
16.00
●
F05.00=35
Customer defined V/F curve scaling, user can set frequency and voltage points
from F05.02~F05.09.
No.
Function
Range
Unit
Default
Type
F05.10
Open Loop Slip
Compensation
0.00
~
200.00
% 150.00
●
Motor rotor speed will reduce as load increases. Start slip compensation to ensure motor
rotor speed close to synchronous speed with the rated load, and increase setting value of
F05.10 appropriately when motor speed is lower than the target value. F05.10=0
,
slip
compensation is disabled.
No.
Function
Range
Unit
Default
Type
F05.11
Stator Voltagedrop
Compensation Gain
0.00
~
100.00
% 80.00
●
F05.12
Excitation Boost Gain
0.00
~
300.00
% 180.00
●
Stator voltagedrop compensation is to compensate voltagedrop produced by stator
resistance and connecting cable.