User Manual
EM100 Mini Inverter
34
3.2.10.3 Wiring the Analog Input Terminals
See Figure 3-15 for wiring terminals VS via analog voltage signal:
When analog voltage input signal is as the external power supply, see Figure 3-15-a for
wiring terminal VS. When analog voltage input signal is as the potentiometer, wire
terminal VS as shown in Figure 3-15-b.
Figure 3-15-a Figure 3-15-b
Figure 3-15 Wiring Terminal VS
See Figure 3-16 for wiring terminals IS via analog current signal:
Figure 3-16 Wiring IS Terminal
3.2.10.4 Wiring Multi-function Input Terminals
Refer to the Figure 3-17 for wiring EM100 multi-function input terminals.
3.2.10.5 Wiring Multi-function Output Terminal
Multi-function output terminal Y1 outputs monitoring signals in OC mode. For instance,
the frequency reach signal in the operation. Details refer to F03.00, F03.01
multi-function output terminal function options. See Figure 3-18 for wiring of OC output
terminal.
Figure 3-17 Wiring Multi-function
Input Terminal
Figure 3-18 Wiring Multi-function Output
Terminal with External Power Supply
Remarks:
When connecting to inductive components (Like relay coil), connect
fly-wheel diode in anti-parallel.
K1
K2
K3
K4
K5
K6
X2
X1
X3
X4
X5
X6
GND