F08.01 Preset Speed 2
0.00
~
Fmax Hz
5.00
●
F08.02 Preset Speed 3
0.00
~
Fmax Hz
10.00
●
F08.03 Preset Speed 4
0.00
~
Fmax Hz
15.00
●
F08.04 Preset Speed 5
0.00
~
Fmax Hz
20.00
●
F08.05 Preset Speed 6
0.00
~
Fmax Hz
25.00
●
F08.06 Preset Speed 7
0.00
~
Fmax Hz
30.00
●
F08.07
Program
Operation
Mode
Ones place: Options of program
operation mode
0: Monocycle
1: Operate as per Preset Speed 7 after
monocycle
2: Limited times of continuous cycle
3: Continuous cycle
Tens place: Options of stop and restart
0: Operate from the period when it
stops
1: Operate from Preset Speed 1
00
〇
F08.08
Program
Operation
Direction
Setting
T
7
T
6
T
5
T
4
T
3
T
2
T
1
0000000
〇
0 0 0 0 0 0 0
0: Forward 1: Reverse
T1 is LSB, arrange in order, the 8
th
bit is
not used.
F08.09
Program
Operation Time
T1
0
~
60000 S
30
●
F08.10
Program
Operation Time
T2
0
~
60000 S
30
●
F08.11
Program
Operation
Section T3
0
~
60000 S
30
●
F08.12
Program
Operation Time
T4
0
~
60000 S
30
●
F08.13
Program
Operation Time
T5
0
~
60000 S
30
●