User Manual
EM100 Mini Inverter
39
DOWN
Select function code, menu or reduce the setting
value of parameter.
Status Indicator
RUN: Green
STOP: Red
F/R: Red
A:Red
V:Red
On: the inverter is running.
Flashing: the inverter is stopping.
On: the inverter fails.
Off: Forward
On: Reverse
Present display data unit is A.
Present display data unit is V.
A and V are on simultaneously if the unit is Hz.
A and V are off if displaying other units.
Keypad
Potentiometer
Regulate speed as per analog value.
4.2 Function Code Check and Editing Method
There are 5 keypad operation modes of EM100: function setting, operation monitoring,
fault monitoring, jog operation, and start/stop. See Table 4-2 for keypad operation modes
and the functions.
Table 4-2 Keypad Operation Modes
Keypad Operation
Mode
Key Function
Function Setting
1.
Display, edit, save, reset and lock the function code and its
parameters.
2.
Reset default of the parameters.
3.
Edit relevant parameter when the inverter is running.
Operation Monitoring
Monitor C00.00-C00.17 parameters when the inverter is
running.
Fault Monitoring
1.
Output frequency, DC bus voltage, and output current
when fault occurs.
2.
The last 3 faults.
Jog Operation
In setting status, press JOG key, the inverter runs as per the
jog numeric frequency. Release the JOG key, the inverter
stops.
Start/Stop
Press RUN and then release in keypad start/stop mode,
inverter starts to run. Press STOP/RESET button in operation
status, inverter stops.
Function setting, operation monitoring and fault monitoring are operated by menu setting.
Start/stop, jog operation and keypad numeric potentiometer are operated by single key.
4.2.1 Main Menu Selection
3 main menu operation options: Function setting, operation monitoring, and fault
monitoring. Function setting menu F00.
_ _
, F01.
_ _
, F02.
_ _
, F03.
_
_
, F04.
_ _
, F05.
_ _
, F06.
_ _
, F07.
_ _
, F08.
_ _
, F09.
_
_
, F10.
_ _
, F11.
_ _
, operation monitoring menu C00.
_ _
, fault
monitoring menu E00.
_ _
. Selecting main menus refers to the following method: