User Manual
EM100 Mini Inverter
64
No.
Function
Range
Unit
Default
Type
F00.07
Primary Numeric
Frequency Setting
0.00
~
Fmax
Hz 0.00
●
F00.08
Auxiliary Numeric
Frequency Setting
0.00
~
Fmax
Hz 0.00
●
F00.07
Operation frequency primary numeric setting value.
The parameter range: 0.00
~
Fmax upper limit frequency.
F00.08
Operation frequency auxiliary numeric setting value.
The parameter range: 0.00
~
Fmax upper limit frequency.
1. Press
/
to edit F00.07 value directly. See Chapter 4 for the shortcut
key description.
2. In primary numeric frequency setting mode, edit F00.07 value by terminal
UP and DOWN directly.
No.
Function
Range
Unit
Default
Type
F00.09
Acceleration Time 1
0.01
~
600.00
S 15.00
●
F00.10
Deceleration Time1
0.01
~
600.00
S 15.00
●
Acceleration time is the time taken for the output frequency to rise from 0Hz up to
maximum frequency Fmax (F00.11). Deceleration time is the time taken for the output
frequency to drop from Fmax (F00.11) down to 0Hz. Both of them are not relevant to
forward and reverse. As shown in Figure 6-5.
(a)
Acceleration Time 1
(b)
Deceleration Time 1
Figure 6-5 Acceleration/ Deceleration Time
2 groups of acceleration/ deceleration times of EM100 can be set as
Terminal for Switching
Acceleration/ Deceleration Time 1/Time 2
by multi-function input terminal. Different
terminal statuses are corresponding to relevant acceleration/ deceleration time. See the
Table 6-5 for the correlation.
Table 6-5 Correlation between acceleration/ deceleration time and its switching terminal
Acceleration/ Deceleration
Terminal Status
Acceleration/ Deceleration Time Option
OFF
Acceleration/ deceleration time group 1(F00.09, F00.10)
ON
Acceleration/ deceleration time group 2(F06.03, F06.04)