Continued
: 5
Indoor unit
ASF-
36AI
S
ASF-
42AI
S
Models
Outdoor unit
ASGE-
36
AI-3 S ASGE-42AI-3 S
kW
10
12
Cooling
Btu/h
34100 40940
kW
10.8
13.0
Nominal
Capacity
Heating
Btu/h
36800 44350
Cooling kW
3.40
4.14
Power
Input
Heating kW
2.90
3.94
EER/COP W/W
2.94/3.72 2.90/3.30
Indoor Unit
Power Supply
-
220~240V-50Hz-1Ph
Heat Exchange
-
Cross Fin Coil
Type
-
Centrifugal
fan
Drive
-
Direct
Driver
Motor Output
kW
0.085×1
Fan
Air Flow
m3/h
1800
Sound Pressure Level(H/M/L)
dB(A)
54/51/48
Air Filter
-
Standard
washable
synthetic
Drain Piping
mm
φ
17×2.5
Dimensions (W×H×D)
(Outline/Package)
mm
1590×238×695/
1714×330×830
Weight(Net/Gross) kg
48/58
Outdoor Unit
Power Supply
-
380~415V-50Hz-3
Ph
220~240V-50Hz-1Ph
Heat Exchange
-
Cross Fin Coil
Type
―
Axial
fan
Motor Output
kW
0.093×1
Fan
Fan Motor Speed (H/M/L)
rpm
780/-/500 820±20
Type
-
ROTARY
Compressor
Power Input
W
3010±7.5%
Type
-
R410A
Control
-
Electronic expansion valve
Refrigerant
Charge kg
2.6
3.5
Dimensions (W×H×D)
(Outline/Package)
mm
980×790×427
/1080×840×485
1107×1100×440
/1155×1220×490
Weight(Net/Gross)
kg
70/78
88/98
Liquid mm
9.52
Gas mm
15.88
Max. Length
m
50
Piping
Connections
Max. Height Difference
m
30
ASF-
36AI
S
ASGE-
36
AI-3 S
ASF-
42AI
S
ASGE-42AI-3 S
Summary of Contents for ASC-18A
Page 2: ...last actualization 2011 ...
Page 27: ...CONTROL ...
Page 47: ...DC INVERTER U MATCH AIR CONDITIONERS CONTROL 5 2 4 Dimensions ...
Page 52: ...INSTALLATION ...
Page 91: ...Wiring diagram ASGE 18AI main board WZD35B 30224042 ...
Page 102: ...96 MAINTENANCE ...
Page 115: ...DC INVERTER U MATCH AIR CONDITION MAINTENANCE 109 Malfunction display E5 Compressor Overheat ...
Page 134: ...DC INVERTER U MATCH AIR CONDITION MAINTENANCE 128 IPM module protection ...
Page 135: ...DC INVERTER U MATCH AIR CONDITION MAINTENANCE 129 DC busbar overvoltage protection ...
Page 136: ...DC INVERTER U MATCH AIR CONDITION MAINTENANCE 130 DC busbar undervoltage protection ...
Page 137: ...DC INVERTER U MATCH AIR CONDITION MAINTENANCE 131 Abnormal noise from PFC inductor ...
Page 138: ...DC INVERTER U MATCH AIR CONDITION MAINTENANCE 132 Radiator overheat protection ...
Page 139: ...DC INVERTER U MATCH AIR CONDITION MAINTENANCE 133 Tripping ...
Page 143: ...DC INVERTER U MATCH AIR CONDITION MAINTENANCE 137 Voltage protection of DC bus ...
Page 155: ...DC INVERTER U MATCH AIR CONDITION MAINTENANCE Model ASGE 36AI ...
Page 157: ...DC INVERTER U MATCH AIR CONDITION MAINTENANCE Model ASGE 42AI 3 S Model ASGE 36AI S ...
Page 158: ...Wiring diagram ASD 18AI old units BATCH CODE 18267 and 18756 main board 30228204 ...
Page 219: ......
Page 221: ...4 Maintenance Exploded View and Spare Parts List Outdoor Unit ASGE 18AI ...
Page 223: ...Model ASGE 24AI old model ASGE 24AI S ...
Page 228: ...Model ASGE 36AI ...
Page 231: ...Model ASGE 36AI S ...
Page 236: ...Model ASGE 36AI 3 S ...
Page 238: ...Model ASGE 42AI 3 ...
Page 241: ...Model ASGE 42AI 3 S 1 PHASE ...
Page 244: ...Exploded View and Spare Parts List DUCT UNITS Indoor Unit ASD 18AI ...
Page 249: ...Exploded View and Spare Parts List CASSETTE UNITS Indoor Unit ASC 18AI ...
Page 255: ...Exploded View and Spare Parts List FLOOR CEILING UNITS Indoor Unit ASF 18AI ...