Continued
: 2
Indoor unit
ASF-
36AI
ASF-
42
AI
Models
Outdoor unit
ASGE-
36A
I-3
ASGE-
42
AI-3
kW
10.0
12.0
Cooling
Btu/h
34100 41000
kW
12.0
14.0
Nominal
Capacity
Heating
Btu/h
40900 48000
Cooling kW
3.4
4.3
Power
Input
Heating kW
4.0
4.8
EER/COP W/W
2.94/3.00 2.79/2.92
Indoor Unit
Power Supply
-
220-240V~/1
Ph/50HZ
Heat Exchange
-
Cross Fin Coil
Type
-
Centrifugal
fan
Drive
-
Direct
Driver
Motor Output
kW
0.085
Fan
Air Flow
m3/h
1800
Sound Pressure Level(H/M/L)
dB(A)
54/51/48
Air Filter
-
Standard
washable
synthetic
Drain Piping
mm
φ
28×1.5
Dimensions (W×H×D)
(Outline/Package)
mm
1590×238×695
/1714×330×830
Weight(Net/Gross) kg
48/58
Outdoor Unit
Power Supply
-
380-415V~/3 Ph/50HZ
Heat Exchange
-
Cross Fin Coil
Type
―
Axial
fan
Motor Output
kW
0.092×2
Fan
Fan Motor Speed (H/M/L)
rpm
940/-/700
Type
-
SCROLL
Compressor
Power Input
W
4160
Type
-
R410A
Control
-
Electronic Expansion Valve
Refrigerant
Charge kg
4.0
Dimensions (W×H×D)
(Outline/Package)
mm
1032×1250×412
/1110×1380×450
Weight(Net/Gross) kg
128/139
Liquid mm
12.7
Gas mm
19.05
Max. Length
m
50
Piping
Connections
Max. Height Difference
m
30
ASF-
36AI
ASF-
42
AI
ASGE-
36A
I-3
ASGE-
42
AI-3
Summary of Contents for ASC-18A
Page 2: ...last actualization 2011 ...
Page 27: ...CONTROL ...
Page 47: ...DC INVERTER U MATCH AIR CONDITIONERS CONTROL 5 2 4 Dimensions ...
Page 52: ...INSTALLATION ...
Page 91: ...Wiring diagram ASGE 18AI main board WZD35B 30224042 ...
Page 102: ...96 MAINTENANCE ...
Page 115: ...DC INVERTER U MATCH AIR CONDITION MAINTENANCE 109 Malfunction display E5 Compressor Overheat ...
Page 134: ...DC INVERTER U MATCH AIR CONDITION MAINTENANCE 128 IPM module protection ...
Page 135: ...DC INVERTER U MATCH AIR CONDITION MAINTENANCE 129 DC busbar overvoltage protection ...
Page 136: ...DC INVERTER U MATCH AIR CONDITION MAINTENANCE 130 DC busbar undervoltage protection ...
Page 137: ...DC INVERTER U MATCH AIR CONDITION MAINTENANCE 131 Abnormal noise from PFC inductor ...
Page 138: ...DC INVERTER U MATCH AIR CONDITION MAINTENANCE 132 Radiator overheat protection ...
Page 139: ...DC INVERTER U MATCH AIR CONDITION MAINTENANCE 133 Tripping ...
Page 143: ...DC INVERTER U MATCH AIR CONDITION MAINTENANCE 137 Voltage protection of DC bus ...
Page 155: ...DC INVERTER U MATCH AIR CONDITION MAINTENANCE Model ASGE 36AI ...
Page 157: ...DC INVERTER U MATCH AIR CONDITION MAINTENANCE Model ASGE 42AI 3 S Model ASGE 36AI S ...
Page 158: ...Wiring diagram ASD 18AI old units BATCH CODE 18267 and 18756 main board 30228204 ...
Page 219: ......
Page 221: ...4 Maintenance Exploded View and Spare Parts List Outdoor Unit ASGE 18AI ...
Page 223: ...Model ASGE 24AI old model ASGE 24AI S ...
Page 228: ...Model ASGE 36AI ...
Page 231: ...Model ASGE 36AI S ...
Page 236: ...Model ASGE 36AI 3 S ...
Page 238: ...Model ASGE 42AI 3 ...
Page 241: ...Model ASGE 42AI 3 S 1 PHASE ...
Page 244: ...Exploded View and Spare Parts List DUCT UNITS Indoor Unit ASD 18AI ...
Page 249: ...Exploded View and Spare Parts List CASSETTE UNITS Indoor Unit ASC 18AI ...
Page 255: ...Exploded View and Spare Parts List FLOOR CEILING UNITS Indoor Unit ASF 18AI ...