Start-Up
4.7
Commissioning
4-97
SINUMERIK 802S
6FC5 597–2AA00–0BP2 (01.02)
Number
Default
Value
Explanation
36040
(only
SPOS)
Delay zero-speed monitoring
0.4
36050
(only
SPOS)
Clamping tolerance
0.5
36060
(only
SPOS)
Maximum velocity/speed ”axis/spindle stopped”
0,0138
36200
Threshold value for velocity monitoring (control parameter set no.): 0...5
31,94
36300
Encoder limit frequency
300000
36302
Encoder limit frequency at which encoder is switched on again. (Hysteresis)
99.9
36310
Zero mark monitoring (encoder no.):
0,1 0: Zero mark monitoring off, encoder
HW monitoring on
1-99, >100: Number of recognized zero mark errors
during
monitoring
100: Zero mark monitoring off, encoder
HW monitoring off
0
36610
Duration of the deceleration ramp for error states
0.05
36620
Cutout delay servo enable
0.1
36700
Automatic drift compensation
0
36710
Drift limit value for automatic drift compensation
1
36720
Drift basic value
0
SD for spindle
Number
Explanation
Default
Value
43210
Progr. spindle speed limitation G25
0
43220
Progr. spindle speed limitation G26
1000
43230
Spindle speed limitation with G96
100
Spindle MD parameterization
Spindle machine data are entered depending on the gear stages. Each gear stage is assigned
a parameter set.
The set of parameters selected corresponding to the current gear stage.
Example:
1st gear stage
set of parameters [1]
Summary of Contents for SINUMERIK 802S
Page 1: ...Start Up 01 2002 Edition SINUMERIK 802S ...
Page 2: ......
Page 8: ...Table of Contents viii SINUMERIK 802S 6FC5 597 2AA00 0BP2 01 02 notice ...
Page 104: ...Start Up 4 7 Commissioning 4 104 SINUMERIK 802S 6FC5 597 2AA00 0BP2 01 02 ...
Page 170: ...Index Index 170 SINUMERIK 802S 6FC5 597 2AA00 0BP2 01 02 notice ...
Page 172: ......