Start-Up
4.1
General
4-51
SINUMERIK 802S
6FC5 597–2AA00–0BP2 (01.02)
Note
The default setting of the machine data is MD10240 SCALING_SYSTEM IS METRIC = 1 (metric).
With the INCH scaling system MD10240=0, MD203=4 (display unit after the decimal).
Default data
This is the default value for the machine or setting data.
Range of values (minimum and maximum values)
... specifies the input limits. If no range of values is specified, then the input limits are defined
by the data type, and the field is marked with ”
∗∗∗
”.
4.1.3
Handling machine data
Handling methods
S
Display
S
Input via keys and V24 interface
S
Making backup copies and reading in/reading out data via the V24 interface
These back–up copies contain
– machine data
– line check sums and
– machine data numbers.
Aborting when loading MD
If incorrect machine data files are read into the control system, an alarm is output.
At the end of reading, an alarm with the number of errors is displayed.
4.1.4
Data saving
Saving data internally
The data in the memory backed up for a limited period can be saved internally in the perma-
nent memory of the control system.
An internal data backup should be carried out if the control system has been switched off for
more than 50 hours (at least 10 min/day with controller ON).
It is recommended to carry out internal data saving whenever important data changes have
been made.
Summary of Contents for SINUMERIK 802S
Page 1: ...Start Up 01 2002 Edition SINUMERIK 802S ...
Page 2: ......
Page 8: ...Table of Contents viii SINUMERIK 802S 6FC5 597 2AA00 0BP2 01 02 notice ...
Page 104: ...Start Up 4 7 Commissioning 4 104 SINUMERIK 802S 6FC5 597 2AA00 0BP2 01 02 ...
Page 170: ...Index Index 170 SINUMERIK 802S 6FC5 597 2AA00 0BP2 01 02 notice ...
Page 172: ......