Technical Appendix
6.1
List of machine and setting data
6-115
SINUMERIK 802S
6FC5 597–2AA00–0BP2 (01.02)
32910
DYN_MATCH_TIME
-
Time constant of dynamic adaption (control parameter set no): 0...5
NEW_CONF
0
0.0
plus
DOUBLE
2/7
32920
AC_FILTER_TIME
s
Smoothing factor time constant for adaptive control
POWER ON
_always
0.0
0.0
plus
DOUBLE
2/7
33050
LUBRICATION_DIST
mm, deg.
Traversing distance for lubrication from PLC
NEW CONF
_always
100000000
0.0
plus
DOUBLE
2/7
34000
REFP_CAM_IS_ACTIVE
-
Axis with reference point cam
RESET
_always
1
***
***
BOOLEAN
2/7
34010
REFP_CAM_DIR_IS_MINUS
-
Approach reference point in minus direction
RESET
_always
0
***
***
BOOLEAN
2/7
34020
REFP_VELO_SEARCH_CAM
mm/min,
rev/min
Reference point approach velocity
RESET
_always
5000.0
0.0
plus
DOUBLE
2/7
34030
REFP_MAX_CAM_DIST
mm, deg.
Maximum distance to reference cam
RESET
_always
10000.0
0.0
plus
DOUBLE
2/7
34040
REFP_VELO_SEARCH_MARKER
mm/min,
rev/min
Creep speed (encoder no.)
RESET
_always
300.0
0.0
plus
DOUBLE
2/7
34050
REFP_SEARCH_MARKER_REVERSE
-
Direction reversal to reference cams (encoder no.)
RESET
_always
0
***
***
BOOLEAN
2/7
34060
REFP_MAX_MARKER_DIST
mm, deg.
Maximum distance to reference mark. Max. distance to 2 reference marks
for distance-coded measuring systems.
RESET
_always
20.0
0.0
plus
DOUBLE
2/7
34070
REFP_VELO_POS
mm/min,
rev/min
Reference point positioning velocity
RESET
_always
1000.0
0.0
plus
DOUBLE
2/7
34080
REFP_MOVE_DIST
mm, deg.
Reference point distance/target point for distance-coded system
RESET
_always
-2.0
-
-
DOUBLE
2/7
34090
REFP_MOVE_DIST_CORR
mm, deg.
Reference point offset/absolute offset distance-coded
POWER ON
_always
0.0
-
-
DOUBLE
2/7
34092
REFP_CAM_SHIFT
mm, deg.
Electr. cam offset of incremental measuring systems with equidistant zero marks
RESET
_always
0.0
0.0
plus
DOUBLE
2/7
34100
REFP_SET_POS
mm, deg.
Reference point value/irrelevant for distance-coded system: 0 ... 3
RESET
_always
0., 0., 0., 0.
-
-
DOUBLE
2/7
Summary of Contents for SINUMERIK 802S
Page 1: ...Start Up 01 2002 Edition SINUMERIK 802S ...
Page 2: ......
Page 8: ...Table of Contents viii SINUMERIK 802S 6FC5 597 2AA00 0BP2 01 02 notice ...
Page 104: ...Start Up 4 7 Commissioning 4 104 SINUMERIK 802S 6FC5 597 2AA00 0BP2 01 02 ...
Page 170: ...Index Index 170 SINUMERIK 802S 6FC5 597 2AA00 0BP2 01 02 notice ...
Page 172: ......