7-157
SINUMERIK 802S
6FC5 597–2AA00–0BP2 (01.02)
Manual Machine
This description should be understood as an addition to the “Start–up Guide for the Sinumerik
802S”. Therefore, only the special features of the Sinumerik 802S with regard to the “Manual
machine” user interface will be described here.
7.1
Hardware and software requirements for the installation
Hardware:
Notice
To ensure that the software is installed successfully when installing the software both for the
first time and whenever installing new software in the future if the “Manufacturer protection
level” is not enabled in the control system, the 802C standard operator panel (OP 020) is re-
quired, in addition to the machine control panel (because of the keys for entering the pass-
word).
The following components are required to install the Sinumerik 802S/C MM software:
S
PG, PC or laptop with CD–ROM drive and serial interface (V24)
S
V24 data cable
S
OP 020 operator panel (standard operator panel); not always required with subsequent
installations (provided that the “Manufacturer protection level” is still enabled in the control)
S
Jumper on connector X1002, pin 24 ––> pin 5 if no machine control panel (MCP) is con-
nected.
Software:
The following requirements must be fulfilled, and the following components must be provided:
S
PG, PC or laptop with operative WinPCIN program (if not yet installed, install it from the
Toolbox)
S
CD ROM with up–to–date toolbox for Sinumerik 802S/C MM
S
At least software version 03.01.06–802S/C or higher must be installed on the Sinumerik
802S/C (otherwise, the operating system must be updated).
7
Summary of Contents for SINUMERIK 802S
Page 1: ...Start Up 01 2002 Edition SINUMERIK 802S ...
Page 2: ......
Page 8: ...Table of Contents viii SINUMERIK 802S 6FC5 597 2AA00 0BP2 01 02 notice ...
Page 104: ...Start Up 4 7 Commissioning 4 104 SINUMERIK 802S 6FC5 597 2AA00 0BP2 01 02 ...
Page 170: ...Index Index 170 SINUMERIK 802S 6FC5 597 2AA00 0BP2 01 02 notice ...
Page 172: ......