Installing the Control System
2.3
Connecting the individual components
2-36
SINUMERIK 802S
6FC5 597–2AA00–0BP2 (01.02)
Signal names
DO0...15
Digital outputs 24V/0.5A
Signal type
V
Voltage input
O
Output (24 V signal)
Table 2-20
Electrical parameters of the digital outputs
Parameter
Value
Unit
Note
“1” signal, nominal voltage
Voltage drop
24
max. 3
V
V
“1” signal, output current
0.5
A
Simultaneity factor
0.5 per 16 outputs
“0” signal, leakage current
max. 2
mA
Connecting sensors and actuators
X2003
X2005
X2004
X2006
0
1
2
3
4
5
6
7
M
L+
0
1
2
3
4
5
6
7
M
8
9
10
11
12
13
14
15
M
L+
8
9
10
11
12
13
14
15
M
IN
OUT
Fig. 2-6
Connecting the digital inputs and outputs