Installing the Control System
2.2
Interfaces and cables
2-20
SINUMERIK 802S
6FC5 597–2AA00–0BP2 (01.02)
Connecting cables
The components are wired up as shown in the Connection Diagram 2-4. For the cables requi-
red, please refer to the diagram below.
ECU
Op. Panel
DI/O16
STEP DRIVE
STEPPER MOTOR
SPINDLE
DRIVE
SPINDLE MOTOR
ENCODER
Handwheels
Sensor (BERO)
Sensor
Actor
Power Supply
P24
M
6FX6002-3AB01-...
6FX6002-2CD01-...
6FX6002-2BB01-...
1...16
1...16
1...4
6FX6002-1AA01-... RS232
Machine
Control
Panel
Wire (1.0...2.5)
Wire (0.14...1.5)
Wire (0.14...1.5)
Flat or round
cable
6FX6002-1AA02-...
6FX6002-3BA31-...
Wire (0.14...1.5)
P24
M
DC24V
RS232
OPI
AXIS
SPINDLE
ENCODER
MPG
DI
IN 0..7
IN 8..15
OUT0..7
OUT8..15
IN
M
IN
M
L+
OUT
M
L+
M
X1
X8
X9
X2
X3
X4
X10
X20
X2003
X2004
X2005
X2006
X1009
X1001
X1002
X1201
X1202
1)
1)
Fig. 2-4
SINUMERIK 802S Connection Diagram
1) Ribbon cable (included in scope of supply)