Installing the Control System
2.4
ENC and operator panel power supply (X1)
2-37
SINUMERIK 802S
6FC5 597–2AA00–0BP2 (01.02)
2.4
ENC and operator panel power supply (X1)
Screw–type terminal block
The 24 V DC load power supply unit required for supplying ENC and operator terminal is con-
nected to screw–type terminal block X1.
Characteristics of the load power supply
The 24 V DC voltage must be generated as a functional extra–low voltage with safe electrical
isolation (to IEC 204-1, Section 6.4, PELV).
Table 2-21
Electrical parameters of the load power supply
Parameter
Min.
Max.
Units
Conditions
Voltage range mean value
20.4
28.8
V
Ripple
3.6
Vss
Non–periodic overvoltage
35
V
500 ms cont.
50 s recovery
Rated current consumption
1
A
Starting current
2.6
A
Pin connector assignment on the ENC side
Table 2-22
Pin connector assignment of screw–type ter-
minal
block X1
Terminal
1
PE
PE
2
M
Ground
3
L+
DC 24 V
4
M
Ground
The contacts 2/4 are connected internally in the device.
Operator panel
The operator panel does not possess a separate power supply connection. It is powered from
the ENC via the signal cables.
Summary of Contents for SINUMERIK 802S
Page 1: ...Start Up 01 2002 Edition SINUMERIK 802S ...
Page 2: ......
Page 8: ...Table of Contents viii SINUMERIK 802S 6FC5 597 2AA00 0BP2 01 02 notice ...
Page 104: ...Start Up 4 7 Commissioning 4 104 SINUMERIK 802S 6FC5 597 2AA00 0BP2 01 02 ...
Page 170: ...Index Index 170 SINUMERIK 802S 6FC5 597 2AA00 0BP2 01 02 notice ...
Page 172: ......