Technical Appendix
6.1
List of machine and setting data
6-116
SINUMERIK 802S
6FC5 597–2AA00–0BP2 (01.02)
34110
REFP_CYCLE_NR
-
Sequence of axes in channel-specific referencing
-1: No obligatory reference point for NC Start
0: No channel-specific reference-point approach
1-15: Sequence in channel-specific reference point approach
RESET
_always
1
-1
31
DWORD
2/7
34200
ENC_REFP_MODE
-
Type of position measuring system
0: No ref. point appr.; if an absolute encoder exists: REFP_SET_POS accepted
1: Zero pulse (on encoder track)
2: BERO
3: Distance-coded reference marks
4: Bero with two edges
5. BERO cam
POWER ON
_always
1
0
6
BYTE
2/7
35010
GEAR_STEP_CHANGE_ENABLE
-
Gear change possible. Spindle has several gear steps
POWER ON
_always
0
***
***
BOOLEAN
2/7
35040
SPIND_ACTIVE_AFTER_RESET
-
Own spindle reset
POWER ON
_always
0
***
***
BOOLEAN
2/7
35100
SPIND_VELO_LIMIT
rev/min
Maximum spindle speed
POWER ON
_always
10000
0.0
plus
DOUBLE
2/7
35110
GEAR_STEP_MAX_VELO
rev/min
Maximum speed for gear change (gear stage no.): 0..5
NEW CONF
_always
500, 500, 1000, 2000, 4000,
8000
0.0
plus
DOUBLE
2/7
35120
GEAR_STEP_MIN_VELO
rev/min
Minimum speed for gear change (gear stage no.): 0..5
NEW CONF
_always
50, 50, 400, 800, 1500, 3000
0.0
plus
DOUBLE
2/7
35130
GEAR_STEP_MAX_VELO_LIMIT
rev/min
Maximum speed of gear stage (gear stage no.): 0...5
NEW CONF
_always
500, 500, 1000, 2000, 4000,
8000
0.0
plus
DOUBLE
2/7
35140
GEAR_STEP_MIN_VELO_LIMIT
rev/min
Minimum speed of gearsetp (gear stage no.): 0...5
NEW CONF
_always
5, 5,10, 20, 40, 80
0.0
plus
DOUBLE
2/7
35150
SPIND_DES_VELO_TOL
Factor
Spindle speed tolerance
RESET
_always
0.1
0.0
1.0
DOUBLE
2/7
35160
SPIND_EXTERN_VELO_LIMIT
rev/min
Spindle speed limitation from PLC
NEW CONF
_always
1000
0.0
plus
DOUBLE
2/7
35200
GEAR_STEP_SPEEDCTRL_ACCEL
rev/s^2
Acceleration in speed control mode [gear stage no.]: 0...5
NEW CONF
_always
30, 30, 25, 20, 15, 10
2
***
DOUBLE
2/7
35210
GEAR_STEP_POSCTRL_ACCEL
rev/s^2
Acceleration in position control mode (gear stage no.): 1...5
NEW CONF
_always
30, 30, 25, 20, 15, 10
2
***
DOUBLE
2/7
35220
ACCEL_REDUCTION_SPEED_POINT
Factor
Speed for reduced acceleration
RESET
_always
1.0
0.0
1.0
DOUBLE
2/7
Summary of Contents for SINUMERIK 802S
Page 1: ...Start Up 01 2002 Edition SINUMERIK 802S ...
Page 2: ......
Page 8: ...Table of Contents viii SINUMERIK 802S 6FC5 597 2AA00 0BP2 01 02 notice ...
Page 104: ...Start Up 4 7 Commissioning 4 104 SINUMERIK 802S 6FC5 597 2AA00 0BP2 01 02 ...
Page 170: ...Index Index 170 SINUMERIK 802S 6FC5 597 2AA00 0BP2 01 02 notice ...
Page 172: ......