Manual Machine
7.7
Operation without machine control panel (MCP)
7-162
SINUMERIK 802S
6FC5 597–2AA00–0BP2 (01.02)
Feedrate:
0 <
Time feedrate
< MD 32020 [1]
$MA_JOG_VELO [1]
0 <
Revolutional feedrate
< MD 32050 [1]
$MA_JOG_REV_VELO [1]
7.7
Operation without machine control panel (MCP)
If you wish to run the control system without machine control panel (MCP), then connect a
jumper between pin 24 and pin 5 to connector X1002 on the installed operator panel; other-
wise, the cotnrol system will not power up.
7.8
I/O assignment in the standard PLC program
The standard PLC program supplied with the Toolbox is designed for subsequent I/O assign-
ments where currently only modules of the DI/O16 type can be used.
7.8.1
Assignment of the digital inputs:
1st module:
I 0.0 *
Reference switch X axis
X2003
Pin 2
DI 0
I 0.1 *
Reference switch Z axis
X2003
Pin 3
DI 1
I 0.2
Limit position X axis
X2003
Pin 4
DI 2
I 0.3
Limit position Z axis (tailstock collision switch)
X2003
Pin 5
DI 3
I 0.4
X2003
Pin 6
DI 4
I 0.5
Chuck guard closed
X2003
Pin 7
DI 5
I 0.6
Lubrication filling level
X2003
Pin 8
DI 6
I 0.7
Lubrication pressure
X2003
Pin 9
DI 7
I 1.0
X2004
Pin 2
DI 8
I 1.1
Protective door closed
X2004
Pin 3
DI 9
I 1.2
Drive ready
X2004
Pin 4
DI 10
I 1.3 *
I2t monitoring of drive tripped
X2004
Pin 5
DI 11
I 1.4
X2004
Pin 6
DI 12
I 1.5
X2004
Pin 7
DI 13
I 1.6
Spindle jogging key
X2004
Pin 8
DI 14
I 1.7
X2004
Pin 9
DI 15
Summary of Contents for SINUMERIK 802S
Page 1: ...Start Up 01 2002 Edition SINUMERIK 802S ...
Page 2: ......
Page 8: ...Table of Contents viii SINUMERIK 802S 6FC5 597 2AA00 0BP2 01 02 notice ...
Page 104: ...Start Up 4 7 Commissioning 4 104 SINUMERIK 802S 6FC5 597 2AA00 0BP2 01 02 ...
Page 170: ...Index Index 170 SINUMERIK 802S 6FC5 597 2AA00 0BP2 01 02 notice ...
Page 172: ......