Installing the Control System
2.3
Connecting the individual components
2-26
SINUMERIK 802S
6FC5 597–2AA00–0BP2 (01.02)
Connector designation:
X3
SPINDLE
Connector type:
9–pin D-Sub plug connector
Table 2-5
Belegung des Steckers X3
X3
Pin
Signal
Type
Pin
Signal
Type
1
SW
VO
6
BS
VO
2
7
1
6
3
8
5
9
4
9
RF.1
K
5
9
5
RF.2
K
for analog drives:
SW
Setpoint
BS
Reference potential for setpoint (analog ground)
RF.1, RF.2
Servo enable contact
Signal type
VO
Voltage output
K
Switching contact
Drives with analog interface
Signals:
One voltage and one enable signal is provided.
S
SW (SETPOINT)
Analog voltage signal in the range of
"
10 V to output a speed setpoint
S
BS (REFERENCE SIGNAL)
Reference potential (analog ground) for the setpoint signal, internally connected to the log-
ics ground
S
RF (SERVO ENABLE)
Relay contact pair used to switch the enable signal for the power section, e.g. a
SIMODRIVE unit. This signal is used by the ENC when the cyclic control mode is started.
Signal parameters
The setpoint is output as an analog differential signal.
Table 2-6
Electrical parameters of the spindle setpoint signal
Parameter
Min.
Max.
Unit
Voltage range
-10.5
10.5
V
Output current
-3
3
mA
Relay contact
Summary of Contents for SINUMERIK 802S
Page 1: ...Start Up 01 2002 Edition SINUMERIK 802S ...
Page 2: ......
Page 8: ...Table of Contents viii SINUMERIK 802S 6FC5 597 2AA00 0BP2 01 02 notice ...
Page 104: ...Start Up 4 7 Commissioning 4 104 SINUMERIK 802S 6FC5 597 2AA00 0BP2 01 02 ...
Page 170: ...Index Index 170 SINUMERIK 802S 6FC5 597 2AA00 0BP2 01 02 notice ...
Page 172: ......