Start-Up
4.3
Starting up the PLC
4-69
SINUMERIK 802S
6FC5 597–2AA00–0BP2 (01.02)
Table 4-8
Generating the addresses for the V range (see user interface)
Type Code
(DB No.)
Range No.
(Channel/
Axis No.)
Subrange
Offset
Addressing
00
(00–79)
00
(00–99)
0
(0–9)
000
(000–999)
symbolic
(8–digit)
Table 4-9
S802S Ranges of operands
Accessed by:
Memory Type
SINUMERIK 802SC
Bit (Byte.bit)
V
14000000.0–79999999.7
I
0.0 – 7.7
Q
0.0 – 7.7
M
0.0 – 127.7
SM
0.0 – 0.6
T
0 – 15
C
0 – 31
L
0.0 – 59.7
Byte
VB
14000000–79999999
IB
0 – 7
QB
0 – 7
MB
0 – 127
SMB
0
LB
0 – 59
AC
0 – 3
Word
VW
14000000–79999998
IW
0 – 6
QW
0 – 6
MW
0 – 126
T
0 – 15
C
0 – 31
LW
0 – 58
AC
0 – 3
Double Word
VD
14000000–79999994
ID
0 – 4
QD
0 – 4
MD
0 – 124
LD
0 – 56
AC
0 – 3