Installing the Control System
2.3
Connecting the individual components
2-31
SINUMERIK 802S
6FC5 597–2AA00–0BP2 (01.02)
VO
Voltage output
I
Input (5 V signal)
Handwheels
Two electronic handwheels can be connected which must meet the following requirements:
Transmission method:
5 V square–wave (TTL level or RS422)
Signals:
Track A as true and negated signal (U
a1
, U
a1
)
Track B as true and negated signal (U
a2
, U
a2
)
Max. output frequency:
500 kHz
Phase offset between
tracks A and B:
90
°
"
30
°
Supply:
5 V, max. 250 mA
2.3.7
Connecting NCREADY (X20)
Pin assignment of the connector on the ENC side
BERO input interface
Connector designation:
X20
DI
Connector type:
10–pin plug connector
Table 2-14Pin assignment of connector X20
X20
Pin
Name
Type
11
NCRDY_1
K
12
NCRDY_2
K
11
13
reserved
DI
14
reserved
DI
15
reserved
DI
16
reserved
DI
17
reserved
DI
18
reserved
DI
20
19
reserved
VI
20
20
reserved
VI
Signal names
NCRDY_1...2
NC Ready (NCREADY contacts 1...2)
BERO1...BERO4
BERO input for axes 1 ... 4
Summary of Contents for SINUMERIK 802S