Start-Up
4.7
Commissioning
4-86
SINUMERIK 802S
6FC5 597–2AA00–0BP2 (01.02)
Number
Description
Default
Value
Setting or Remark
36000
Exact positioning coarse
0.04
0.5
36010
Exact positioning fine
0.01
0.1
36020
Delay exact positioning fine
1.0
4
36060
Maximum velocity/speed ”axis/
spindle stopped”
5.0
20
Parameterization example
Stepper motor: 10,000 [pulses per motor revolution]
Load gear:
1:1
Leadscrew pitch:
10 mm
Motor speed:
1,200 rpm
MD 30130
=2
MD 30240
=3
MD 31400
=10,000
MD 32260
=1,200 rpm
MD 32000
=12,000 mm/min
Stepper motor frequency
The parameterization is carried out using the machine data, which have already been mentio-
ned, after POWER-ON.
The resulting stepper motor frequency is displayed with machine data MD 31350.
Motor speed [rpm]
S
steps per stepper motor revolution
MD 31350 [Hz]=-------------------------------------------------–––––––––––––––––––
60 [s]
This frequency must correspond to MD 32000.
Supplementary conditions
Servo gain
The default setting of the servo gain when controlling stepper motors without measuring sy-
stem is K
v
= 2.5 (MD: 32200, limit approx. 2.5).
Max. stepper motor frequency
The max. permissible stepper motor frequency is 500 kHz.
Summary of Contents for SINUMERIK 802S
Page 1: ...Start Up 01 2002 Edition SINUMERIK 802S ...
Page 2: ......
Page 8: ...Table of Contents viii SINUMERIK 802S 6FC5 597 2AA00 0BP2 01 02 notice ...
Page 104: ...Start Up 4 7 Commissioning 4 104 SINUMERIK 802S 6FC5 597 2AA00 0BP2 01 02 ...
Page 170: ...Index Index 170 SINUMERIK 802S 6FC5 597 2AA00 0BP2 01 02 notice ...
Page 172: ......