Technical Appendix
6.1
List of machine and setting data
6-118
SINUMERIK 802S
6FC5 597–2AA00–0BP2 (01.02)
36050
CLAMP_POS_TOL
mm, deg.
Clamping tolerance
NEW CONF
_always
0.5
0.0
plus
DOUBLE
2/7
36060
STANDSTILL_VELO_TOL
mm/min,
rev/min
Maximum velocity/speed ”axis/spindle stopped”
NEW CONF
_always
5 (0.014)
0.0
plus
DOUBLE
2/7
36100
POS_LIMIT_MINUS
mm, deg.
1st software limit switch minus
RESET
_always
-100000000
-
-
DOUBLE
2/7
36110
POS_LIMIT_PLUS
mm, deg.
1st software limit switch plus
RESET
_always
100000000
-
-
DOUBLE
2/7
36120
POS_LIMIT_MINUS2
mm, deg.
2nd software limit switch minus
RESET
_always
-100000000
-
-
DOUBLE
2/7
36130
POS_LIMIT_PLUS2
mm, de-
grees
2nd software limit switch plus
RESET
_always
100000000
-
-
DOUBLE
2/7
36200
AX_VELO_LIMIT
mm/min,
rev/min
Threshold value for velocity monitoring
(control parameter set no.): 0...5
NEW CONF
_always
11500., 11500., 11500.,
11500., ...
0.0
plus
DOUBLE
2/7
36300
ENC_FREQ_LIMIT
Hz
Encoder limit frequency
POWER ON
_always
300000
0
plus
DOUBLE
2/7
36302
ENC_FREQ_LIMIT_LOW
%
Encoder limit frequency at which encoder is switched on again. (Hysteresis)
NEW CONF
_always
99.9
0
100
DOUBLE
2/7
36310
ENC_ZERO_MONITORING
-
Zero mark monitoring (encoder no.): 0,1
0: Zero mark monitoring off, encoder HW monitoring on
1-99, >100: Number of recognized zero mark errors during monitoring
100: Zero mark monitoring off, encoder HW monitoring off
NEW CONF
_always
0, 0
0.0
plus
DWORD
2/7
36500
ENC_CHANGE_TOL
mm, deg
portion of distance for backlash working
NEW CONF
_always
0,1
0.0
plus
DOUBLE
2/7
36610
AX_EMERGENCY_STOP_TIME
s
Duration of the deceleration ramp for error states
NEW CONF
_always
0.05
0.0
plus
DOUBLE
2/7
36620
SERVO_DISABLE_DELAY_TIME
s
Cutout delay servo enable
NEW CONF
_always
0.1
0.0
plus
DOUBLE
2/7
36700
DRIFT_ENABLE
-
Automatic drift compensation
NEW CONF
_always
0
***
***
BOOLEAN
2/7
Summary of Contents for SINUMERIK 802S
Page 1: ...Start Up 01 2002 Edition SINUMERIK 802S ...
Page 2: ......
Page 8: ...Table of Contents viii SINUMERIK 802S 6FC5 597 2AA00 0BP2 01 02 notice ...
Page 104: ...Start Up 4 7 Commissioning 4 104 SINUMERIK 802S 6FC5 597 2AA00 0BP2 01 02 ...
Page 170: ...Index Index 170 SINUMERIK 802S 6FC5 597 2AA00 0BP2 01 02 notice ...
Page 172: ......