Technical Appendix
6.2
PLC user interface signals
6-129
SINUMERIK 802S
6FC5 597–2AA00–0BP2 (01.02)
Decoded M signals (M0 – M99)
2500
M functions from NCK channel [r]
Data block
Interface NCK
Byte
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
Dynamic M functions
25001000
M7
M6
M5
M4
M3
M2
M1
M0
Dynamic M functions
25001001
M15
M14
M13
M12
M11
M10
M9
M8
Dynamic M functions
25001002
M23
M22
M21
M20
M19
M18
M17
M16
...
...
...
Dynamic M functions
25001012
M99
M98
M97
M96
25001013
25001014
25001015
Notes:
+ Static M functions must be generated by the PLC user from the dynamic M functions.
+ Dynamic M functions are decoded by the basic program (M00 to M99).
Transferred T functions
2500
T functions from NCK channel [r]
Data block
Interface PLC
Byte
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
25002000
T function 1 (DINT)