Macro 30 - ASi Single slave with fixed setpoints (default ASi)
Note
Unswitched and switched power supply
The unswitched 24 V power supply (also known as non-switched) on X1.2 and X1.4 provides
power to the general electronics of the Control Unit. The switched 24 V power supply on X1.1
and X1.5 supplies power for the two digital outputs (DI0 and DI1).
For a complete explanation of the unswitched and switched 24 V supplies and their limitations,
please read the FAQ at the following link:
Unswitched and switched 24 V supply (
http://support.automation.siemens.com/WW/view/
)
Installation
4.3 Electrical Installation
Distributed converter for SIMOGEAR geared motors
Operating Instructions, 10/2020, FW V4.7 SP13, A5E31298649B AL
81