p1020
p1021
p1022
p1023
Resulting setpoint
1
0
0
1
p1001 + p1004
0
1
0
1
p1002 + p1004
1
1
0
1
p1001 + p1002 + p1004
0
0
1
1
p1003 + p1004
1
0
1
1
p1001 + p1003 + p1004
0
1
1
1
p1002 + p1003 + p1004
1
1
1
1
p1001 + p1002 + p1003 + p1004
Selecting the fixed speed setpoint, binary
)L[HGVSHHGVHWSRLQWVHOHFWLRQELW
)L[HGVSHHGVHWSRLQWVHOHFWLRQELW
)L[HGVSHHGVHWSRLQWVHOHFWLRQELW
)L[HGVSHHGVHWSRLQWVHOHFWLRQELW
)L[HGVSHHGVHWSRLQW
)L[HGVSHHGVHWSRLQW
)L[HGVSHHGVHWSRLQWHIIHFWLYH
)L[HGVSHHGVHWSRLQW
)L[HGVSHHGVHWSRLQW
)L[HGVSHHGVHWSRLQW
U
S
S
S
S
S
S
S
S
S
Figure 8-45
Binary selection of the fixed speed setpoint
Table 8-51
Resulting setpoint
p1020
p1021
p1022
p1023
Resulting setpoint
0
0
0
0
0
1
0
0
0
p1001
0
1
0
0
p1002
1
1
0
0
p1003
0
0
1
0
p1004
1
0
1
0
p1005
0
1
1
0
p1006
1
1
1
0
p1007
0
0
0
1
p1008
1
0
0
1
p1009
0
1
0
1
p1010
1
1
0
1
p1011
0
0
1
1
p1012
1
0
1
1
p1013
0
1
1
1
p1014
1
1
1
1
p1015
Advanced commissioning
8.16 Setpoints
Distributed converter for SIMOGEAR geared motors
266
Operating Instructions, 10/2020, FW V4.7 SP13, A5E31298649B AL