4.1
Mechanical Installation
Dimensions of the system
The converter has two frame sizes. Frame size A (FSA) and Frame size B (FSB), the dimensions
of each frame size is given in the figure and table below.
*ODQGHGYDULDQW
+$14YDULDQW
+
/
'
:
:
'
'
'
Figure 4-1
Dimensions of the converter
Table 4-1
Converter dimensions
Frame size
H
(mm)
L
(mm)
D1
(mm)
D2
(mm)
D3
(mm)
W (mm)
without glands
A
135
270
208
216
161
132
B
135
309
208
216
181
132
Clearance distance
The G110M system requires a minimum clearance distance around and above the converter of
150 mm.
PP
PP
PP
PP
PP
PP
PP
Figure 4-2
G110M Clearance distances
Installation
4.1 Mechanical Installation
Distributed converter for SIMOGEAR geared motors
38
Operating Instructions, 10/2020, FW V4.7 SP13, A5E31298649B AL