Table 8-10
Set two-wire control, ON/reverse in quick commissioning
Parameter
Description
p0015 = 12
Macro drive unit
Assigning digital inputs to the commands:
• Digital input 0: ON/OFF1
• Digital input 1: Reversing
Wiring example for the factory settings (Page 80)
Parameter
Parameter
Description
Factory setting
p0840[C]
BI: ON/OFF (OFF1)
0
p1113[C]
BI: Setpoint inversion
0
r0722.0…n
CO/BO: CU digital inputs, status
-
p3334
2/3 wire control selection
0: Two-wire control, ON/reverse
0
Advanced commissioning
8.5 Controlling clockwise and counter-clockwise rotation via digital inputs
Distributed converter for SIMOGEAR geared motors
Operating Instructions, 10/2020, FW V4.7 SP13, A5E31298649B AL
173