
17
.
PROFIBUS / USS address and basic commissioning DIP-
switches
There are three sets of DIP-switches that allow the user to con‐
figure the network device address and perform a basic commis‐
sioning of the system.
Quick Commissioning with DIP switches (Page 108)
2
18
.
PROFIBUS / USS network termination switch
When using the PROFIBUS or USS communications protocols,
the last converter on the network must have the network termi‐
nation switch in the ON position.
2))
21
19
.
Fit memory card into the Power Module
To allow parameter settings to be stored or copied to the con‐
verter, the memory card must be fitted into the memory card
reader.
Installation
4.2 System Installation
Distributed converter for SIMOGEAR geared motors
Operating Instructions, 10/2020, FW V4.7 SP13, A5E31298649B AL
53