You transferred the settings to the converter.
❒
10.2.1.4
Download from the PC using Startdrive
Overview
You can transfer the converter settings that have been backed up to a PC back to the converter.
Requirement
The following preconditions apply:
• The PC and converter are connected with one another.
• The converter settings are not protected against copying.
Download with active know-how protection with copy protection (Page 375)
Function description
Procedure
1. Open the Startdrive project that matches the drive.
2. Select "Load to device".
3. Confirm the prompt for saving your settings (copy RAM to ROM).
You transferred the settings from the PC to the new converter.
❒
10.2.2
Converter with enabled safety functions
10.2.2.1
Automatic download from the memory card
Overview
We recommend that you insert the memory card before switching on the converter. The
converter automatically imports its settings from the inserted memory card.
Requirement
The following preconditions apply:
• The converter power supply has been switched off.
• The converter settings are not protected against copying.
Download with active know-how protection with copy protection (Page 375)
Corrective maintenance
10.2 Downloading the converter settings
Distributed converter for SIMOGEAR geared motors
370
Operating Instructions, 10/2020, FW V4.7 SP13, A5E31298649B AL