Installing/Mounting
5.4 Distributed configuration
SIMOTION P320-3 and Panel Fronts
Manual, 02/2012
85
5.4
Distributed configuration
5.4.1
Overview of decentralized structure
The distributed configuration makes it possible to connect SIMOTION panel fronts in
different physical locations to a SIMOTION P320-3. The greater flexibility in terms of location
allows the SIMOTION P320-3 to be positioned in non-critical areas of a plant (e.g. control
cabinet).
The essential characteristics of a Panel PC Remote Kit are as follows:
● Signal transmission between SIMOTION P320-3 and SIMOTION panel front via DVI-D
and USB or USB extender cable
● The distance between the SIMOTION P320-3 and the SIMOTION panel front can be up
to 30 m
● Graphics resolutions: 800 x 600 to 1024 x 768 pixels; color resolution: 16 bits (specific to
the panel front used)
● Interfaces on the remote module:
– DVI-D interface
– USB computer interface (> 5 m) RJ45
– 2 x USB 2.0 for the connection of external USB devices
– USB computer interface (≤ 5 m) USB B
– Interfaces to the SIMOTION panel front:
LVDS interface (picture signals)
I/O USB interface (keys)
USB interface (for connection to front-mounted USB interface)
● External 24 VDC power supply required
Note
Using a distributed configuration with the Panel PC Remote Kit reduces the data rate at the
USB interface on the SIMOTION panel front.
See also
Summary of Contents for SIMOTION P320-3
Page 14: ...Safety notes 1 2 Recycling and disposal SIMOTION P320 3 and Panel Fronts 14 Manual 02 2012 ...
Page 32: ...Description 2 4 SIMOTION panel fronts SIMOTION P320 3 and Panel Fronts 32 Manual 02 2012 ...
Page 100: ...Connecting 6 7 PROFINET strain relief SIMOTION P320 3 and Panel Fronts 100 Manual 02 2012 ...
Page 140: ...Standards and approvals A 3 Certificates SIMOTION P320 3 and Panel Fronts 140 Manual 02 2012 ...