Troubleshooting/FAQs
8.1 General problems
SIMOTION P320-3 and Panel Fronts
106
Manual, 02/2012
Problem
Possible cause
To correct or avoid error
USB device not
responding
The operating system
does not have a suitable
driver for the USB device.
Install a suitable driver; the correct driver can often be
downloaded from the homepage of the device's manufacturer.
The EWF for Windows Embedded Standard 2009 must first be
disabled for this purpose.
IP address assigned twice
(e.g. through series
commissioning).
Default IP address for
Windows (see
SIMOTION P320-3 and
Panel Fronts
Commissioning and
Hardware Installation
Manual)
Assign a new IP address for Windows (see SIMOTION P320-3
and Panel Fronts Commissioning and Hardware Installation
Manual).
This must be different to the previous default IP address and may
not have been assigned already in the network.
Error message during
project download.
(Download of the HW
configuration not
possible)
When the write filter is
activated, a project
download can only be
performed when no
changes have been made
in the HW configuration.
Deactivate the write filter and restart the project download.
If the problem is not corrected by deactivating the write filter, then
contact your technical support team in this case (see Hotline and
Summary of Contents for SIMOTION P320-3
Page 14: ...Safety notes 1 2 Recycling and disposal SIMOTION P320 3 and Panel Fronts 14 Manual 02 2012 ...
Page 32: ...Description 2 4 SIMOTION panel fronts SIMOTION P320 3 and Panel Fronts 32 Manual 02 2012 ...
Page 100: ...Connecting 6 7 PROFINET strain relief SIMOTION P320 3 and Panel Fronts 100 Manual 02 2012 ...
Page 140: ...Standards and approvals A 3 Certificates SIMOTION P320 3 and Panel Fronts 140 Manual 02 2012 ...