Status displays on the device
PWR
GREEN
Indicates correct supply voltage of 3.3 V, 5 V and 12 V from the
integrated power unit
WD
OFF
Not relevant.
OFF
SIMOTION P is operating without error.
RED: Slow flashing (0.5 Hz)
No license exists for technology/optional objects under license.
Carry out the licensing to correct the error.
Further information on the licensing can be found in the
SIMOTION P320-3 and Panel Fronts Commissioning and
Hardware Installation Manual.
RED: Fast flashing (2 Hz)
A fault has occurred to which the user program cannot respond.
The following actions may be required to rectify the fault:
Power OFF/ON
New commissioning procedure
SF (Group fault)
RED
An interrupt which can be acknowledged is present (alarm,
message, note).
(See Diagnostics Guide)
OFF
SIMOTION P Runtime is not running
YELLOW
SIMOTION P in STOP mode
RUN/STOP
GREEN
SIMOTION P in RUN mode
OFF
SIMOTION P is operating without error.
RED: Slow flashing (0.5 Hz)
Underlicensing
RED: Fast flashing (2 Hz)
No or faulty configuration
SF PROFINET
RED
Acknowledgeable event
Summary of Contents for SIMOTION P320-3
Page 14: ...Safety notes 1 2 Recycling and disposal SIMOTION P320 3 and Panel Fronts 14 Manual 02 2012 ...
Page 32: ...Description 2 4 SIMOTION panel fronts SIMOTION P320 3 and Panel Fronts 32 Manual 02 2012 ...
Page 100: ...Connecting 6 7 PROFINET strain relief SIMOTION P320 3 and Panel Fronts 100 Manual 02 2012 ...
Page 140: ...Standards and approvals A 3 Certificates SIMOTION P320 3 and Panel Fronts 140 Manual 02 2012 ...