Hardware description
3.3 SIMOTION P320-3 interfaces
SIMOTION P320-3 and Panel Fronts
44
Manual, 02/2012
3.3.4
PROFINET interface
Interface assignment
Designation: X3, PROFINET (LAN), three ports P1, P2, P3
Type: 8-pin RJ45 socket
Table 3- 3
X3 interface assignment (ports P1, P2, P3)
PROFINET interface
/('
/('
Pinno.
Short designation Meaning
Input / output
1
RD+
Receive data *
Input
2
RD-
Receive data *
Input
3
TD+
Transmit data *
Output
4, 5
1)
SYMR
Internal 75 Ohm terminating resistor
_
6
TD-
Receive data *
Output
7, 8
1)
SYMT-
Internal 75 Ohm terminating resistor
_
S
Shield
LED 1
Lights up green: Link
LED 2
Lights up yellow: Activity
* Auto negotiation and auto cross over are supported