DISPLAY MODULE AND OFFICE CONFIGURATION EDITOR
_________________________________________________________________________________________________________
3-118
SIG-00-22-02 JUNE 2022 (Revised September 2022)
Version: B.1
•
Maintenance Call output
•
Advance Preempt OP
•
Gate Down OP
•
Second Train OP
Figure 3-173 Web UI Logical View
If the blue arrow next to the logic term is selected this will show a detailed view of each AND,
OR or Equations as shown in figures: Figure 3-174, Figure 3-175, and Figure 3-176.
If a term is negated, then its LED will show green when the underlying term is off, e.g., NWP1 is
on, so the !NWP is off, so the LED is grey.