DISPLAY MODULE AND OFFICE CONFIGURATION EDITOR
_________________________________________________________________________________________________________
3-92
SIG-00-22-02 JUNE 2022 (Revised September 2022)
Version: B.1
Table 3-2 Connections allowing TSS and Gnd Fault Tester
PSO Card Present
RIO Present
Empty Slot
OUT 2.3
IN 2.1
OUT 2.3
OUT 3.3
OUT 3.3
OUT 4.3
IN 4.1
OUT 4.3
OUT 5.3
IN 5.1
OUT 5.3
The SSCC inputs on SSCC Module 1 (SSCC1 VI-1 thru SSCC1 VI-5) and SSCC Module 2
(SSCC2 VI-1 thru SSCC2 VI-5) are also available to be used for Ground fault tester and MTSS
inputs provided that they are not being used by the GCP Programming.
The two inputs on the front of the SEAR (DI1 (J3) and DI2 (J3)) are also available to be used for
the Ground fault tester and MTSS.
When an input is selected with algorithm MTSS, the options shown in Figure 3-139 are
available.
.
Figure 3-139 SEAR Digital Inputs TSS Options