BASIC APPLICATION GUIDELINES & PROGRAMMING
_________________________________________________________________________________________________________
5-12
SIG-00-22-02 JUNE 2022 (Revised September 2022)
Version: B.1
•
Int.1 Sets PSO 1 RX1 Enable
•
Int.1 Set by PSO 4 RX1 Occupancy
•
Int.2 Sets PSO 1 RX1 Enable
•
Int.2 Set by PSO 5 RX1 Occupancy
Note that assigning an internal channel multiple times effectively ANDs the terms setting it, so in
the case above either PSO 4 or 5 RX1 Occupancy de-energizing will de-energize PSO 1 RX 1
Enable.
5.2.5 Stick Cancel Input
NOTE
The Stick Cancel input should “normally” be energized. De-energizing the
input will cancel and set sticks and not allow another stick to be set.
The GCP5000(GCE) allows an external input to be used to cancel a stick. To use this
•
Set the Stick Cancel Input Used to Yes on the PSO ‘n ‘Transmitter menu
•
Assign the Stick Cancel input to an input (or it can be set by internal logic) for example,
•
IN 7.1 PSO 1 Stick Cancel.
De-energizing the input causes the stick to be canceled.
NOTE
If a PSO Enable input is used and wired to an external PSO 4000, the
Health output from this PSO can be wired to a Stick Cancel output on the
GCE, this will prevent a failure of the external PSO resulting in the Stick
for the exit track remaining set.