2.1.1.3 PSO Module Alternate II (US&S AFO) Frequency Data
Table 2-3 provides maximum operating distance and frequency grouping data for frequencies
used by US&S AFO units.
The maximum operating distances shown, are between transmitter and receiver track wire
connections for end-fed track circuits. For center-fed track circuits, double the distances given to
obtain the maximum receiver-to-receiver distance.
NOTE
The alternate frequencies depicted in Table 2-3 are those typically used
by US&S equipment and are available for use with GCE. However, the
alternate frequencies use Siemens modulation patterns and are not
directly compatible with non- Siemens transmitters or receivers.
Table 2-3 Maximum Operating Distances at 0.06-Ohm Shunting Sensitivity
for PSO Module Alternate II (US&S AFO) Frequencies
APPLICATION GROUP
FREQUENCY
(HZ)
BALLAST
2
Ω
/1,000 FT.
OPERATING
DISTANCE (FT./M)
3
Ω
/1,000 FT.
OPERATING
DISTANCE (FT./M)
4
Ω
/1,000 FT.
OPERATING
DISTANCE (FT./M)
P
S
O
M
O
DULE
A
LT
E
RNA
T
E
I
I
(U
S&S
A
F
O
) F
R
EQ
U
EN
C
IES
1
1000
1250
1500
1750
2300
2800
4000/1219
3500/1067
3300/1006
2900/884
2600/792
2400/732
4300/1311
3950/1204
3700/1128
3250/991
2950/899
2700/823
4600/1402
4400/1341
4100/1250
3600/1097
3300/1006
3000/914
2
1125
1375
1640
1875
2175
2675
3800/1158
3400/1036
3000/914
2800/853
2700/823
2500/762
4150/1265
3800/1158
3300/1006
3150/960
3050/930
2800/853
4500/1372
4200/1280
3600/1097
3500/1067
3400/1036
3100/945