Table 1-2 Frequencies Available for Use with PSO Module
APPLICATION TYPE
FREQUENCIES UTILIZED
PSO Module Standard Frequencies
(Hz)
156, 211, 285, 348, 430, 525,
645
,
790
,
970
,
1180
,
1450
,
1770
,
2140
,
2630
,
3240
,
4000
PSO Module Alternate I (Harmon
AFTAC II) Frequencies (Hz)
500, 700,
900
, 1100,
1300
, 1600, 1640,
2300
, 2800,
3100
, 3500,
4000
,
4900, 5400, 5900, 6400, 7100, 7700, 8300, 8900, 9500, 10200
PSO Module Alternate II (US&S
AFO) Frequencies (Hz)
1000, 1100, 1125, 1250, 1375, 1500, 1640, 1750, 1875, 2175, 2300, 2675,
2800
(Frequencies in
Bold
text are recommended for use in electrified territories)
Table 1-3 Island Frequencies Available for Use with PSO Module
APPLICATION TYPE
FREQUENCIES UTILIZED
PSO Module Standard Island
Frequencies (Hz)
2.14 kHz
,
2.63 kHz
,
3.24 kHz
,
4.00 kHz
, 4.90 kHz, 5.90 kHz, 7.10 kHz,
8.30 kHz, 10.0 kHz, 11.5 kHz, 13.2 kHz, 15.2 kHz, 17.5 kHz, 20.2 kHz
PSO Module
Alternate I (Harmon AFTAC II) and
Alternate II (US&S AFO)
Island Frequencies (Hz)
2.3 kHz
,
2.8 kHz
,
3.1 kHz
,
3.5 kHz
,
4.0 kHz
, 4.9 kHz, 5.4 kHz, 5.9 kHz,
6.4 kHz, 7.1 kHz, 7.7 kHz, 8.3 kHz, 8.9 kHz, 9.5 kHz, 10.2 kHz
(Frequencies in
Bold
text are recommended for use in electrified territories)
1.5 System Specifications
Table 1-4 Input Power Specifications
PARAMETER
RANGE OF VALUES
Battery Voltage
On CPU Connector:
9.0-16.5 VDC
On SSCC IIIi Connector:
9.0-16.5 VDC
Maximum Ripple:
1.0V p-p