Upload a parameter set with an MMC
Prerequisites
To upload a parameter set the following important conditions must be fulfilled:
● An inverter with an appropriate parameter set is available (upload inverter).
● An MMC Type 6SL3254-0AM00-0AA0 is available.
● Supply voltage is active for the upload inverter.
● The upload inverter is in "Ready to Run"".
● The parameters are copied from RAM to EEPROM.
Procedure
Note
During a parameter upload from the EEPROM to a MMC (e.g. for serial commissioning) the
LEDs are flashing.
If the Control Unit is in a faulty state, the fault will be displayed by the LEDs (SF on, RDY
off).
Parameter
Description (Parameter name and factory setting (if not variable) in bold)
Setting
Insert the MMC to the inverter - for the parameter set to be uploaded, perform the following
steps:
P0010 = 30
Commissioning parameter*
0: Ready
1: Quick commissioning
2: Inverter
30: Factory setting, parameter transfer
95: Safety commissioning (for CUs with fail-safe functions only)
P0804 = …
Select Clone file
0: clone00.bin
…
99: clone99.bin
Note: Via P0804 the name of the clone file can be selected. Theoretically up to 100 (0 … 99)
parameter sets can be stored on an MMC.
Note:
Before uploading, the parameters will be copied from RAM to EEPROM.
P0802 = 2
Transfer data from EEPROM
0: Disabled
1: Start BOP Transfer
2: Start MMC Transfer
If the upload has been completed successfully, P0010 and P0802 will be set to 0 and the
"RDY" LED is on.
If the upload has failed, F0061 (MMC-PS not fitted) or F0051 (failure while accessing
EEPROM) will be displayed, LED "SF" (red) is on.
In this case insert an MMC and attempt another upload.
After a successful upload remove the MMC from the upload inverter to insert it into the
download inverter.