Communication
6.1 PROFIdrive Profile V4.1
Control Units CU240S
126
Operating Instructions, 07/2008 - FW 3.2, A5E00766042B AD
Regulation for the parameter range
The bit for parameter page selection functions as follows:
If it is set to 1, an offset of 2000 is applied in the inverter to the parameter number (PNU)
transferred in the parameter channel request before it is passed on.
,1'
D G F E I
H
Figure 6-5
IND page index acyclic
,1'
D G F E I
H
Figure 6-6
IND page index cyclic
Table 6-4
Regulation for setting the PNU
Page index
Bit
Parameter range
a
d
c
b
f
e
9
8
Hex value
+ PNU
0000 … 1999
0
0
0
0
0
0
0
0
0x00
0 – 7CF
2000 … 3999
1
0
0
0
0
0
0
0
0x80
0 – 7CF
4000 … 5999
0
0
0
1
0
0
0
0
0x10
0 – 7CF
6000 … 7999
1
0
0
1
0
0
0
0
0x90
0 – 7CF
8000 … 9999
0
0
1
0
0
0
0
0
0x20
0 – 7CF
…
…
…
…
…
…
…
… …
…
…
32.000 … 33.999
0
0
0
0
0
1
0
0
0x04
0 – 7CF
…
…
…
…
…
…
…
… …
…
…
64.000 … 65.999
0
0
0
0
1
0
0
0
0x08
0 – 7CF
Table 6-5
Example coding for parameter no. in PKE and IND for P8820, Index 16
PKE
IND
decimal
xx
820
32
16
hex
xx
334
20
10