Chapter 10
Operating Instructions
ICR845-2 Image Code Reader
142
©
SICK AG · Division Auto Ident · Germany · All rights reserved
8012377/ 0000/ 2008-01-30
Appendix
10.4.5
Functions of CLV-Setup
The CLV-Setup program (from V. 4.1) features functions to carry out the following:
10.4.6
Hot keys
[F1]
Start "CLV-Setup Help" online
[F2]
Open dialog box to execute device functions
[F3]
Upload complete set of parameters from ICR845-2
[F4]
Download complete set of parameters to ICR845-2
[F5]
Open configuration file
[F6]
Save configuration file
[F7]
Load default setting of ICR845-2 from CLV-Setup database
[F8]
Start AutoBaud Detect
[F9]
Load operating data from ICR845-2 to be displayed and reset
[F10] Open Terminal Emulator
Group
Function
Communcation
Automatic communication attempt with the ICR845-2 when the program is started
AutoBaud detect for automatic serial communication establishment with the ICR845-2
Selecting the COM port of the PC for adapting the data transfer parameters
Automatic software compatibility check in the ICR845-2
Display
Selecting the display language
Selecting the units of measure
Displaying the last 10 configuration files that were processed
Image output of the read code via the Ethernet interface (ICR845-2 only)
Monitor the data communication of the ICR845-2 host interface
Operation
Changing the parameter/parameter values on the tabs
Online access to the ICR845-2 via a Terminal Emulator (selecting operating mode, starting oper-
ating functions, logging file for communication between the ICR845-2 and CLV-Setup, extended
terminal mode, e.g. for displaying ICR845-2 messages)
Hot keys [F keys] for essential functions (program operation without a mouse)
Macro player for recording and playing a macro file
Context-sensitive help via the
[
F1
]
key
Assistants
CLV Assistant for simplified parameterization
Wizards for individual functions
Upload/Download
Uploading and displaying parameter set stored in the ICR845-2
Downloading the changes to the parameter set in the ICR845-2
Administration
Loading the default setting of the parameter set from the database of CLV-Setup
Saving the changes to the parameter set as a configuration file "*.scl"
Automatic storage confirmation prompt when changes are made to the configuration file
Organizing serveal devices logically by projects
Saving the device type that was selected last
Setting switches in the "CLVmain.ini" file for starting the program
Starting program with SCL file as argument
Clearing the optional CMC600 parameter memory in the connection module CDB/CDM
Export
Exporting the configuration files in RTF format
Exporting the command strings contained in the profile bar codes in ASCII format
Printing
Printing the configuration files
Printing the parameter set in the form of profile bar codes (not for ICR845-2)
Tab. 10-3: Functions of the CLV-Setup configuration software (overview)