![SICK ICR845-2 Operating Instructions Manual Download Page 87](http://html.mh-extra.com/html/sick/icr845-2/icr845-2_operating-instructions-manual_1264254087.webp)
Operating Instructions
Chapter 6
ICR845-2
Startup and configuration
8012377/0000/2008-01-30
©
SICK AG · Division Auto Ident · Germany · All rights reserved
87
s
3.
To return to Reading mode, click the R
EADING
M
ODE
radio button or close the Terminal
Emulator.
The ICR845-2 returns to Reading mode.
The code number "1500" means that the self-test was completed successfully and that no
faults were diagnosed.
Chapter 8.3 Error messages, Page 106
lists the error key together with the associated cor-
rective measures.
6.9.8
Code statistics for RDT400
Function of the auxiliary interface. In this mode, the ICR845-2 outputs a data string with sta-
tistic information on the reading situation.
For detailed description of the functions and applications of the Remote Diagnostic Tool
RDT400 see the RDT400 Operating Instructions (no. 8009385, English).
"Code statistics for RDT400" is activated via the A
UXILIARY
I
NTERFACE
tab.
1.
Select the C
ODE STATISTICS FOR
RDT400 option on the A
UXILIARY
I
NTERFACE
tab.
2.
Perform a download to the ICR845-2.
To do so, click the listing field again with the right mouse button and choose D
OWNLOAD
P
ARAMETER
in the context menu.
CLV-Setup copies the parameter temporary to the ICR845-2.
The auxiliary interface then operates in "Code statistics for RDT400" mode until the
ICR845-2 is switched off again.
Fig. 6-26:
CLV-Setup: Displaying the self-test result in the Terminal Emulator