Chapter 10
Operating Instructions
ICR845-2 Image Code Reader
130
©
SICK AG · Division Auto Ident · Germany · All rights reserved
8012377/ 0000/ 2008-01-30
Appendix
2.
Adjust the following parameter values:
"2D reading parameters" section: minimum/maximum cell size 2D
The cell size setting is a key factor in the reading quality:
If the ICR845-2 is to read symbols with different cell sizes, the area of the cell sizes that
occur must be set here.
Adjust the minimum cell size in line with the code to be read. The minimum cell size
should be slightly smaller than the cell size in the code layout.
Adjust the maximum cell size in line with the code to be read. The maximum cell
size should be slightly larger than the cell size in the code layout.
The smaller the range between the minimum and maximum cell size the shorter will be the
decoding time.
b) Setting the symbol size
1.
Select the C
ODE
C
ONFIGURATION
tab.
2.
Click the E
DIT
button in the 2D-S
YMBOLOGIES
section.
The D
ATA
M
ATRIX
tab opens.
Fig. 10-6:
CLV-Setup: "Code configuration" tab
Fig. 10-7:
CLV-Setup: "Data Matrix" tab