Chapter 6
Operating Instructions
ICR845-2 Image Code Reader
94
©
SICK AG · Division Auto Ident · Germany · All rights reserved
8012377/ 0000/ 2008-01-30
Startup and configuration
6.13
Configuration guide
6.13.1
Overview of configuration procedure
Adjusting the optical reading characteristics
Setting up reading pulse
Configuring the evaluation characteristics of the decoder
Configuring the output characteristics (data, result status)
Defining the function of the auxiliary interface
When the ICR845-2 is started up for the first time, the factory default setting is in effect.
The following parameters must then be set:
6.13.2
Adjusting optical reading characteristics
General:
Code quality R
EADING
C
ONFIGURATION
tab I
MAGE PROCESSING
section M
ARKING
METHOD
section
Evaluation range of the reading area R
EADING
C
ONFIGURATION
tab R
EADING
P
ARAME
-
TERS
2-D section A
REA OF INTEREST
section (CP values)
Illumination mode R
EADING
C
ONFIGURATION
tab I
MAGE
P
ROCESSING
section and C
ODE
P
ROPERTIES
P
ARAMETERS
button I
NTERNAL
I
LLUMINATION MODE
section
Object velocity R
EADING
C
ONFIGURATION
tab I
MAGE PROCESSING
section and C
ODE
P
ROPERTIES
P
ARAMETERS
button G
LOBAL CAMERA SETTINGS
section Object velocity
For 2D codes (Data Matrix ECC200):
Minimum cell size R
EADING
C
ONFIGURATION
tab R
EADING PARAMETERS
2D section
Configuring (if necessary):
– Image brightness
R
EADING
C
ONFIGURATION
tab I
MAGE PROCESSING
section C
ODE
P
ROPERTIES
P
ARAMETERS
button G
LOBAL CAMERA SETTINGS
section Brightness (Gain)
– For ink-jet printing: Compensation of poor dot size
R
EADING
C
ONFIGURATION
tab
I
MAGE PROCESSING
section C
ODE
P
ROPERTIES
P
ARAMETERS
button G
LOBAL CAMERA SET
-
TINGS
section Diavation of dot size
– Contrast improvement
R
EADING
C
ONFIGURATION
tab I
MAGE PROCESSING
section
C
ODE
P
ROPERTIES
P
ARAMETERS
button G
LOBAL CAMERA SETTINGS
section Contrast
(Gamma correction)
– Illumination mode
R
EADING
C
ONFIGURATION
tab C
ODE
P
ROPERTIES
P
ARAMETERS
but-
ton I
NTERNAL
I
LLUMINATION
M
ODE
section
– See also
Chapter 10.2.1 Improving the image quality, Page 127
If necessary setting up ofdynamic parameter switchings R
EADING
C
ONFIGURATION
tab
D
YNAMIC PARAMETER SWITCHING ACTIVE
button
For bar codes:
Minimum bar width R
EADING
C
ONFIGURATION
tab R
EADING PARAMETERS
1D section
Configuring (if necessary):
– Bar saturation
R
EADING
C
ONFIGURATION
tab I
MAGE PROCESSING
section C
ODE
P
ROPERTIES
P
ARAMETERS
button S
ETTINGS
1D S
MART
/S
TANDARD
D
ECODER
section
Satuaration of bars
See also