Chapter 8
Operating Instructions
ICR845-2 Image Code Reader
112
©
SICK AG · Division Auto Ident · Germany · All rights reserved
8012377/ 0000/ 2008-01-30
Troubleshooting
4. ICR845-2 stops reading with delay after
the end of reading pulse
(Pulse mode: sensor input(s), serial inter-
face)
Trigger mode: one external sensor
Stop delay for "Sensor 1"
parameterized incorrectly
Trigger mode: two external sensors
Debouncing for "Sensor 2" switching
parameterized incorrectly
Stop delay for "Sensor 2"
parameterized incorrectly
Check with CLV-Setup:
Select the D
EVICE
C
ONFIGURATION
tab, click
the R
EADING
T
RIGGER
P
ARAMETERS
button.
S
TOP DELAY
section: Values set by mis-
take?
Time controlled: selected value too high?
Track controlled: incremental encoder
connected to "Sensor 2" input, ICR845-2
parameterized correctly?
Check with CLV-Setup:
Select the D
EVICE
C
ONFIGURATION
tab, S
EN
-
SOR
2 section: correct the values for de-
bouncing.
Download to the ICR845-2.
Check with CLV-Setup:
Select the D
EVICE
C
ONFIGURATION
tab, click
the R
EADING
T
RIGGER
P
ARAMETERS
button.
S
TOP DELAY
section: Values set by mis-
take?
Time controlled: selected value too high?
Fault
Possible cause
Remedy
Tab. 8-4: Troubleshooting: Reading pulse errors in Reading mode (contd.)