Operating Instructions
Chapter 10
ICR845-2
Appendix
8012377/0000/2008-01-30
©
SICK AG · Division Auto Ident · Germany · All rights reserved
139
10.4.3
Starting "CLV-Setup"
The "CLV-Setup" program is launched with the following default settings:
Data communication via the serial auxiliary interface (RS 232):
1.
Switch on the PC and start Windows
2.
Choose CLV-Setup from the Start menu.
The introductory dialog box is displayed after the identifier for the SICK software.
3.
Confirm the initial screen with "OK".
CLV-Setup then checks whether an ICR845-2 is connected to the COM 1 port on the PC
and whether the communication parameters on the PC match those on the ICR845-2.
If this is the case, the
"Connected"
status is displayed with the ICR845-2 specification
on the bottom, right-hand side in the status bar. The detected device type is displayed
in the toolbar in the D
EVICE
drop-down list (in this case: ICR845).
The software then loads the internal device description of the ICR845-2 and the defaults
settings of the parameter values from its database and displays these on the tabs. The soft-
ware then copies the current parameter set from the memory (RAM) of the ICR845-2. This
is displayed on the tabs instead of the default settings.
You can edit the current parameter set on the tabs. The default values are displayed when
the device is used for the first time.
Troubleshooting
If CLV-Setup cannot establish a connection with the ICR845-2, it displays "
No connection"
in
the status field on the bottom, right-hand side. There are two possible causes for this. The
ICR845-2 is not connected or the communication parameters of the ICR845-2 do not match
those of the PC. In this case, CLV-Setup enters the device type of the device it last commu-
nicated with in the D
EVICE
drop-down list on the toolbar. The default setting is CLV41x the
first time CLV-Setup is started. The software then loads the internal device description for
this type and the default settings of the parameter values from its database and displays
these on the tabs.
Communication
COM 1 (RS 232), 9,600 bd, 8 data bits, 1 stop bit, no parity
Transmit control character
Start: STX, Stop: ETX
Receive control character
Start: STX, Stop: ETX
Unit of measure
Metric (depending on the selected installation)
Browser
user dependent
Language
As selected for the installation
Company name
As entered for the installation
User name
As entered for the installation
Establish connection to ICR845-2
automatically
At startup: Yes
On scanner selection: Yes
When the Terminal Emulator is started/ closed: Yes
Initial screen
Yes
Storage confirmation prompt
Yes
Last type selected
CLV41x
File storage location
"data" (configuration files for ICR845-2)
Tab. 10-2: Default settings in CLV-Setup (extract)