![SICK ICR845-2 Operating Instructions Manual Download Page 79](http://html.mh-extra.com/html/sick/icr845-2/icr845-2_operating-instructions-manual_1264254079.webp)
Operating Instructions
Chapter 6
ICR845-2
Startup and configuration
8012377/0000/2008-01-30
©
SICK AG · Division Auto Ident · Germany · All rights reserved
79
100 %= Identification quality
ST
= Read status (ST = 0: Good Read)
CP
= Code position
CL
= Code length (character count)
CA
= Scanning expenditure
CS
= Code security
CK
= Code continuity
DI
= Decoding direction,
F = in counting direction of the CP,
R = against counting direction of the CP
MC
= Multi Count (number of multiple readings), 8-digit
MC = 1: the ICR845-2 has read the code one time in the image
(e.g. on output mode "immediate")
DP
= The ICR845-2 has successfully read the code in the last recorded
image with the Dynamic Parameter Switching no. 1
3. Output of reading result: No Read
The structure of the reading result for No Read is identical for 2D codes and bar codes.
TT=__55 ms MG=_63 % n=_0
no code!
with:
1st line: TT
= Reading interval time
MG
= Long-term mean value of identification quality
n
= Number of recognized codes
2nd line: no code = No code found!
Triggering the reading pulse via the Terminal Emulator
In the default setting, the "Sensor 1" switching input is the trigger source of the reading
pulse. The reading pulse can also be triggered directly via the terminal emulator of CLV-Set-
up for test purposes. To do so, a different trigger source must be selected temporarily in the
ICR845-2.
1.
Choose the D
EVICE
C
ONFIGURATION
tab.
2.
Click the R
EADING
T
RIGGER
P
ARAMETERS
button.
The R
EADING
T
RIGGER
P
ARAMETERS
dialog box is then displayed.
3.
Click the S
ERIAL
I
NTERFACE
radio button in the S
TART OF READING INTERVAL
section.
4.
Perform a download to the ICR845-2.
To do so, click the S
ERIAL
I
NTERFACE
option again with the right mouse button and choose
D
OWNLOAD
P
ARAMETER
in the context menu.
CLV-Setup copies the parameter temporary to the ICR845-2.
The serial interface has been activated as the trigger source of the reading pulse and
is ready to receive appropriate commands (until the ICR845-2 is switched off).
5.
Click on
in the toolbar.
The Terminal Emulator dialog box is then displayed.
6.
Click R
EADING
M
ODE
under D
EVICE
M
ODE
.