Configuring the SDC 8200 system
112
Making a system diagnosis
Displaying the number of consoles connected to the central unit
To display the number of consoles connected to the central unit:
왘
From the central unit’s operating menu, choose “
System
”,
“
Diagnostics
” and “
Port Status
” one after the other.
The ports „
P1
“ to „
P6
“ with their respective number of connected
consoles are shown on the display.
Checking the communication within a cable string
To display if and on which port(s) a communications error has occured:
왘
From the central unit’s operating menu, choose “
System
”,
“
Diagnostics
” and “
Port Errors
” one after the other.
The ports „
P1
“ to „
P6
“ with a respective symbol are shown on the
display.
The symbols have the following meanings:
: A cable string with consoles is connected to the port.
: No cable string is connected to the port. If this symbol appears even
though a cable string is connected to the port, check if the cable string
is connected correctly.
[!]
: A communications error has occured. This symbol only appears if a
cable string is connected to the port.
Configuring connected additional components
Turning on/off a camera control
If you connect an external camera control to the central unit, you have to
activate the camera control via the central unit’s operating menu.
To turn a connected camera control on:
왘
From the central unit’s operating menu, choose “
System
” and “
Camera
Control
” one after the other.
The current status of the camera control is shown on the display.
왘
Choose “
Status = ON
” and press the ENTER key to save your setting.
Diagnostics
1
Port Status
Port Status
15 15 14 02 15 15
P1 P2 P3 P4 P5 P6
Diagnostics
1
Port Errors
Port Errors
[!]
P1 P2 P3 P4 P5 P6
System
2
Camera Conrol
Camera Control
Status = OFF