2-26
10
Set the paper tube flange.
Slowly pull the media out straight, and fix the paper tube flange
at the position, 3-5 mm from the media edge by evenly screwing
the three screws at the paper tube flange's outer side.
Rotate the take-up roll referring to the NOTE 1 below, and
confirm that the two paper tube flanges do not swing at all.
3 to 5mm gap to be secured
at the both media edges
Paper tube flange fixing
screws at three positions
NOTE1
Rotate the take-up roll with the procedure below.
(a) Cover the sensor window by sliding your hand downward as shown by the
arrow of the figure below. Note that the take-up roll is rotated only with the
sensor's downstroke shielding.
(b) By keeping the sensor window covered, the take-up roll rotates for 4 seconds
and stops.
(c) When the take-up roll needs to be rotated more, repeat the steps (a) and (b).
Sensor window
–